faucet.valve ERROR DPID 55930 (0xda7a) switch1 OFError type: OFPET_FLOW_MOD_FAILED code: OFPFMFC_UNKNOWN version=0x4,msg_type=0x1,msg_len=0x4c,xid=0x9518de33,OFPErrorMsg(code=0,data=bytearray(b’x04x0ex00@x95x18xde3x00x00x00x00Zxdcx15xc0x00x00x00x00x00x00x00x00x01x00x00x00x00x00Px00xffxffxffxffx00x00x00x00x00x00x00x00x00x00x00x00x00x01x00x0ex80x00x08x06x00x00x00x00x01x02x00x00′),type=5) caused by version=0x4,msg_type=0xe,msg_len=0x40,xid=0x9518de33,OFPFlowMod(buffer_id=4294967295,command=0,cookie=1524372928,cookie_mask=0,flags=0,hard_timeout=0,idle_timeout=0,instructions=[],match=OFPMatch(oxm_fields={‘eth_src’: ’00:00:00:00:01:02′}),out_group=0,out_port=0,priority=20480,table_id=1)
vlans:
100:
name: "vlan100"
description: "VLAN 100"
faucet_mac: "00:00:00:00:01:01" # MAC address of Faucet for this VLAN
faucet_vips: ["192.168.100.254/24"] # Faucet VIPs for this VLAN
unicast_flood: True # Allow unicast flooding within VLAN
max_hosts: 255 # Maximum number of hosts allowed in VLAN
200:
name: "vlan200"
description: "VLAN 200"
faucet_mac: "00:00:00:00:01:02" # MAC address of Faucet for this VLAN
faucet_vips: ["192.168.200.254/24"] # Faucet VIPs for this VLAN
unicast_flood: True # Allow unicast flooding within VLAN
max_hosts: 255 # Maximum number of hosts allowed in VLAN
dps:
switch1:
dp_id: 0xda7a
hardware: "Open vSwitch"
interfaces:
1:
name: "port1"
description: "Port 1"
2:
name: "port2"
description: "Port 2"